RealLine HPV HCR Screen

A QUALITATIVE ASSAY KIT FOR THE DETECTION OF DNA OF THE HIGH CARCINOGENIC RISK TYPES 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66 AND 68 OF THE HUMAN PAPILLOMA VIRUS BY REAL TIME PCR

 

CE-IvD marked on many real-time PCR devices

 

Ready to use – completely lyophilized

Intended use

Clinical information:

Human Papilloma Viruses HPV are DNA-Viruses and in between are more than 100 different types are known. While the majority of HPVs cause no symptoms, some can cause low severe symptoms like warts and a few are known to cause cancer. HPV types that are more likely to lead to the development of cancer are referred as high-risk types HPV. High-risk HPV-types are known to cause the vast majority of cervical cancers which cause death in women with an annual incidence of around half a million and a mortality of almost 50 %.

The RealLine HPV HCR Screen assay kit is designed for the detection of DNA of

  • HPV type 16
  • HPV type 18
  • HPV type 31
  • HPV type 33
  • HPV type 35
  • HPV type 39
  • HPV type 45
  • HPV type 51
  • HPV type 52
  • HPV type 56
  • HPV type 58
  • HPV type 59
  • HPV type 66
  • HPV type 68

The extraction of DNA from clinical materials can be performed using the extraction kits:

  • RealLine DNA-Express (REF VBC8899-R)
  • RealLine Extraction 100 (REF VBC8896-R)
  • INSTANT Virus RNA/DNA Kit – IPC16 (Roboscreen GmbH, Germany)
  • INSTANT Virus RNA/DNA Kit – FX (Roboscreen GmbH, Germany)
  • VeriLab UMag (Laboveritas SIA)

When using DNA extraction kits of other manufacturer, it is necessary to use Internal Control sample (IC) (VBC8881, BIORON Diagnostics).

The assay is based on the real-time polymerase chain reaction (PCR) method with fluorescent detection of the amplified product. The results of PCR analysis are taken into account in complex diagnostics of disease.

The kit is validated for use with: iQ™ 5 iCycler (Bio-Rad, USA). The kit is compatible with real-time PCR systems such as CFX™96 (Bio-Rad, USA) and DT-96 (DNA-Technology, Russia) and RealLine Cycler (BIORON Diagnostics GmbH).

The use of:

!  Extraction Kits for nucleic acids from clinical specimen from other supplier

!  other real-time PCR devices

!  appropriate reaction volumes, other than 50 µl

has to be validated in the lab by the user. The special notes regarding the internal control IC have to be strongly followed.

Status

CE IvD

Validated extraction kits

RealLine DNA-Express (REF VBC8899-R)

RealLine Extraction 100 (REF VBC8896-R)

INSTANT Virus RNA/DNA Kit – IPC16 (Roboscreen GmbH, Germany)

INSTANT Virus RNA/DNA Kit – FX (Roboscreen GmbH, Germany)

VeriLab UMag (Laboveritas SIA)

Validated real-time PCR platforms

The kit is validated for use with: iQ™ 5 iCycler (Bio-Rad, USA). The kit is compatible with real-time PCR systems such as CFX™96 (Bio-Rad, USA) and DT-96 (DNA-Technology, Russia) and RealLine Cycler (BIORON Diagnostics GmbH).

Specifications

Sensitivity

Sensitivity of detection of DNA HPV types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66 and 68 (on four samples, containing 100 DNA copies, prepared from Standard Reference Samples) equals 100 %.

Specificity

Specificity of detection of DNA HPV types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66 and 68 (using Standard Reference Panel of negative DNA-extracts) equals 100 %.

Diagnostic evaluation

Diagnostic sensitivity

Diagnostic sensitivity of DNA detection of human papilloma virus of high cancer risk: clinical trials, conducted on 95 positive samples showed a 100 % sensitivity (range 97% -100%, with 90% confidence level).

Diagnostic specificity

Diagnostic specificity of DNA detection of human papilloma virus of high cancer risk: clinical trials, conducted on 54 negative samples showed a 100 % specificity (range 95 % -100 %, with 90 % confidence level).

Order information

Item number Kit size
VBD8444 96 reactions
   
RealLine Internal Control Kit size
VBC8881 250 reactions